Temperature Control Meter Of PVC Card Laminator AU2000-5 Laminator Spare Part
Each function is used:
1. In the stop state, the meter displays the measured value and the lower row shows “Stp”.
2. Heating starts when cold start, the heating indicator lights up, the upper row of the meter displays the temperature measurement value, and the lower row shows the value of TH.
When the measured value is greater than the TH value, the heating is stopped and the heating indicator is off.
3. The delay indicator lights up, the meter starts to delay, the upper row shows the delay time, and the lower row shows the value of dt.
When the delay time is greater than the dt value, the delay indicator is off.
4. When the fan starts, the cooling indicator lights up, and the temperature reduction process starts. The upper row of the meter displays the temperature measurement value, and the lower row shows the value of SPL.
When the measured value is less than the TL value, the fan stops and the cooling indicator turns off.
5. The buzzer starts to beep, the alarm indicator lights up, the alarm process begins, the upper row shows the alarm time, and the lower row shows the value of At.
When the alarm time is greater than the At value, the buzzer stops and the alarm indicator turns off.
6. Enter the stop state
7. Re-power on repeat 2~6
Main technical performance:
Measurement accuracy | 0.5% ± 1 dig |
Power supply voltage | 220VAC |
Temperature environment | 0-50 ° C |
Fuzzy PID control | |
Opening distance (mm) | CYE type 67.5*67.5 |